In-Stock
1/2" x 4' x 8' STRUCTODEK HD
USES
STRUCTODEK HD with Primed Red Coating can be used as:
Insulation board
Cover board
Re-roof/recover board
Designed for low-slope single-ply and traditional roof system applications
High-density roofing board for both new construction and re-roofing
ASTM C208, Type II, Grade 1 and Grade 2
Federal Specification LLL-I-535 (superseded by ASTM C208)
CAN/ULC-S706-09 Type II, Classes 1 and 2
UL Classified, Std UL 790
ULC Classified, Std CAN/ULC-S107
FM Approved Class 1 – FM Standards 4450/4470
DORA Listed – RCM ID #689
Canadian Evaluation – CCMC #13186-L
Florida Building Code Product Approval – FL #13792.1
Miami-Dade County NOA – No. 23-0623.03 (Expires 09/18/2028)
Compatible with:
PVC, TPO, EPDM, CSPE single-ply membranes
Most low-VOC, water-based, and traditional adhesives
Direct peel-and-stick applications
Superior adhesion with minimal adhesive absorption
BUR compatible – easily handles hot asphalt
Approved in:
Thousands of FM RoofNav® assemblies
UL Class A and Class 1 rated roof systems
Environmentally friendly:
Green, non-asphaltic coating
Contributes to LEED credits
Durability & strength:
Hail resistant
Structurally rigid
Handles heavy foot traffic and wheeled loads
Sound & thermal performance:
Contains SOUNDSTOP® sound-deadening technology
R-value of 1.3 per ½” thickness
Easy to work with:
Lightweight
Fiberglass-free
Cuts with a standard utility knife
High compressive strength:
25 psi @ 10% deformation
62 psi @ 20% deformation
Dual-side Primed Red coating:
Optimized for surface bonding
Ideal for use in single- and multi-ply systems
Superior moisture resistance:
Wax and moisture-resistant additives integrated during manufacturing
Protects edges and core, including jobsite cuts
Cost-effective – engineered for performance and value
Do not expose to open flame or excessive heat
May smolder if ignited – extinguish completely
Do not apply flame directly when installing modified bitumen systems
Must be kept dry at all times (in storage and during installation)
Only install as much as can be covered by the completed roofing system the same day
Not intended for use under shingles
In re-roofing:
Remove all wet areas of the existing roof
Remove all loose and protruding gravel
Avoid use near:
Chimneys
Heater units
Fireplaces
Steam pipes
Other heat sources exceeding 212°F without proper protection
Always follow heating appliance manufacturer’s guidelines
Fastening patterns should follow the roofing membrane manufacturer’s specifications
Property | ½” Thickness Value | 1” Thickness Value |
---|---|---|
Transverse Strength (lbf) | 12 – 14 | 24 |
Weight (lb/ft², nominal) | 0.7 | 1.375 |
Tensile Strength Parallel (min, psi) | 150 | 150 |
Tensile Strength Perpendicular (psi) | 600 | 600 |
Water Absorption (vol, max %) | 7 | 7 |
Moisture Content (weight, max %) | 10 | 10 |
Linear Expansion (50–90% RH, max %) | 0.5 | 0.5 |
Modulus of Rupture (min, psi) | 275 | 140 |
Deflection at Min Load (max, in.) | 0.75 | 0.42 |
Flute Spanability (max width, in.) | 1-5/8 | 2-5/8 |
Compressive Strength (min, psi) | 15 | 15 |
R-Value (ft²·h·°F/BTU per in.) | 1.3 | 2.5 |